Introduction: Molarity (M) is used to determine concentration. Molarity is found by dividing the number of moles of a solute by the volume of the solution in liters. Multiple series of solutions with different concentrations can be used by diluting the concentration. The dilution technique is: Number Moles Concentrated Solution = Number Moles Dilute Solution. An instrument called a spectrophotometer detects the amount of light that passes through the sample and the percent transmittance can be recorded from the meter. In the lab, multiple homogeneous solutions are made. There was not a way to determine the differences in concentrations, but the Spec 20 made it possible to measure the difference. The Beer-Lambert Law is a graph used to record …show more content…
The wavelength was set to absorbance of 600 nm, which is the max for Cu2+. Ten small test tubes were cleaned and a piece of label tape was placed around the top of each tube. A vertical straight line was drawn on the tape to help align with the mark on the instrument sample holder. The transmittance of the Spec 20 was set to 0% using the left-hand adjustment knob while the well was empty and closed. One test tube was filled 3/4 full of a blank solution (distilled water). A Kimwipe was used to wipe off any solution on the outside of the test tube. The test tube was then placed into the empty well with both the mark on the test tube and the mark on the well aligned. The lid of the well was closed. The right-hand adjustment knob was used for setting the transmittance to …show more content…
Once recorded, it was possible to find the absorbance of the solution by using the equation: A=2-log(%T). The Beer-Lambert Law was used to provide a calibration plot on the relationship between absorbance and concentration. From Figure 1, the calibration curve shows the absorbance vs. concentration of the standard solutions of Cu2+. Figure 2 shows absorbance vs. concentration of concentrations made. The solutions in figure two were found my using the formula MC * VC = MD * VD. Concentration of molarity and volume were given from previous information in the lab. Dilution of molarity was also used from previous information form the lab. Dilution of volume was found using basic algebra. The VD plus water must equal 20 mL to create each made solution. Concentration is defined as molarity. It is found by dividing the number of moles of solute by the volume of solution in liters. Absorbance is defined as the amount of wavelengths taken in by the

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Molar Mass Lab

    • 478 Words
    • 2 Pages

    also have 1.44 g/ 178.2 g / mole of the solute = 0.00808 moles in 12.89 g of solvent…

    • 478 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Experiment 3 prelab

    • 345 Words
    • 2 Pages

    The objectives of this lab include- illustrating the use of the spectrophotometer in chemical analysis, and generating a standard, or calibration curve, then using that curve to determine the value of an unknown substance. The spectrophotometer is one of the most powerful tools used in chemistry to find the concentration of substances in solution. It compares the colors of a known and an unknown solution, that comparison then leads to a quantitative estimate of the concentration of trace amounts of colored materials in that solution.…

    • 345 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Lab Report

    • 2156 Words
    • 9 Pages

    The entire experiment is based on the results from the calibration curve. The calibration curve is used to generate an equation that is then used to calculate molarity. This value is then converted to the desired unit, milligrams. So, to obtain the calibration curve data, two students began by preparing two solutions. The first was 100 mL of 1.0 x 10-3 M Fe(NO3)3, and the second was 100 mL of 0.10 M KSCN. Both solutions were made in 1.0 HNO3. The former solution was prepared using 0.0404 grams of Fe(NO3)3•9H2O on an analytical balance (calculations below). The latter solution was prepared using 0.97 grams of KSCN on a top loading balance (calculations below). Then, 1.0 mL of the iron nitrate solution was added to 100 mL of the KSCN solution and mixed. Being that the spectrophotometer (the instrument being used to measure absorbance) was already zeroed by the teaching assistant, the construction of the calibration curve could begin. To start, the cuvette was filled with the current mixture, placed into the spectrophotometer, and the absorbance was recorded. The cuvette was then emptied back into the beaker containing the entire solution, as not to skew the overall volume, and therefore the concentration.…

    • 2156 Words
    • 9 Pages
    Good Essays
  • Satisfactory Essays

    Before we put each dilution in the SPEC 20, we put water in a cuvette and put it in the SPEC 20 so we could zero out the percent transmittance.…

    • 796 Words
    • 4 Pages
    Satisfactory Essays
  • Good Essays

    In order to complete the objective, the group used a Carolina Digital Spectrophotometer, unit M 201-1, which measures the quantity of light that solutions absorb. The spectrophotometer consists of a light source that shines through a prism which then shines through a…

    • 1159 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Using a spectrophotometer, the absorbance, A, of a solution measured directly. FeSCN2+ is placed into the spectrophotometer and their absorbances at 447nm are measured.…

    • 849 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    When it came to recording data for my experiment, I placed the cuvette in the spectrometer, which was set to 500nm, after adding the guaiacol and hydrogen peroxide right before. I recorded the absorbance every 15 seconds for 3 minutes. I ran the experiment twice for precision and got the average of the two tests.…

    • 267 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    The 2nd graph was between concentration and absorbance. This is a direct relationship because as the concentration increased, the absorbance also increased. For this graph, the line should touch the origin because it is a positive slope going from lower values to higher values. Also it passes through the origin because direct variation relationships are in the form of y = mx, where y and m are constant variables. For the absorbance value to zero, the concentration must be also be zero.…

    • 304 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Penny Lab

    • 1143 Words
    • 5 Pages

    The purpose of this lab is to determine the percent mass of Cu in a penny and see if the fabricator that makes the planchets for the government is using the correct amounts of Cu in the pennies. The composition of a standard penny is 97.5% Zn and 2.5% Cu. In the lab we will be using Beer’s Law (A=elc+b where A is solution absorbance, e is a constant called molar absorbency, l is the length in cm, and c is the concentration). Using Beer’s Law in this lab a colorimeter is used to find the absorbance and from this the concentration of dissolved Cu2+ ions can be found and percent mass calculated. The techniques used in this lab are useful in that they provide little human error for various parts of the lab by taking the measurements by a colorimeter human error is reduced.…

    • 1143 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Beer-Lambert Law

    • 557 Words
    • 3 Pages

    In this lab, the Beer-Lambert Law is tested by using a spectrophotometer. This is a quick and easier way to determine the concentration of a solution.…

    • 557 Words
    • 3 Pages
    Good Essays
  • Good Essays

    experiment were 0.25M and 0.35M. The concentration of the samples were found by using a…

    • 3353 Words
    • 14 Pages
    Good Essays
  • Good Essays

    Beer-Lambert Law

    • 372 Words
    • 2 Pages

    Use the value of the molar absorptivity of Cu2+(aq) at 635 nm to determine the concentration of two unknown Cu2+(aq) solutions based on the empirical…

    • 372 Words
    • 2 Pages
    Good Essays
  • Good Essays

    The concentration of an unknown CuSO4 solution is then determined by measuring its absorbance with the Colorimeter. By locating the absorbance of the unknown on the vertical axis of the graph, the corresponding concentration can be found on the horizontal axis. The concentration of the unknown can also be found using the slope of the Beer’s law curve.…

    • 862 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    This lab will teach me how to use a spectrophotometer. The use of the spectrophotometer is to measure the concentration of solute. The solute being measured must be colored and is determined based on the adsorption of light photons on a wavelength. The spectrophotometer uses a beam of light that strikes the diffraction grating that basically forms of prism of light. Then only a specific wavelength of light shines through the spectrophotometer and interacts with the solute. The light that continues past the solute hits the phototube. The spectrophotometer then digitally shows the amount of units that have been absorbed or transmitted. Transmittance is the amount of light that gets through the sample. This is shown as a percent of all the possible light that could’ve gotten through. Absorbance is the opposite of transmittance and the reciprocal of it. This shows how much light got trapped in the solute. In this lab we will use a few different solutions in the spectrophotometer to get a basic feel on how it works. We will record the absorbance as well as do calculations using mean and standard deviation. We will then graph our results and compare them with the class values of the three unknown Methylene blue samples. At the end of the lab the actual concentrations of each unknown will be shared. We will then compare how accurate and precise our results are with the actual.This lab will teach me how to use a spectrophotometer. The use of the spectrophotometer is to measure the concentration of solute. The solute being measured must be colored and is determined based on the adsorption of light photons on a wavelength. The spectrophotometer uses a beam of light that strikes the diffraction grating that basically forms of prism of light. Then only a specific wavelength of light shines through the spectrophotometer and interacts with the solute. The light that continues past the solute hits the phototube. The spectrophotometer…

    • 1420 Words
    • 6 Pages
    Satisfactory Essays
  • Powerful Essays

    The objectives of this experiment are to understand why and how spectroscopy is used to determine the components and concentrations of a solution, describe various types of spectroscopy, describe the visible and ultraviolet regions of the electromagnetic spectrum, define Beer’s law and define the relationship between absorbance and transmittance. Other learning objectives are to create a Beer’s law plot for a series of samples with known concentrations, collect spectrophotomic data from unknown and known FDC blue dye samples, perform serial dilutions, calculate concentrations, perform linear regression and determine the equation of a best fit line.…

    • 1297 Words
    • 8 Pages
    Powerful Essays